Where a roof is to be used for any purpose other than weather protection the vent extensions shall be run at least seven feet above the roof.
How high does a roof vent pipe need to be.
If the pipe is farther than 10 feet from the roof peak it must be 2 feet above the highest point of the roof within 10 feet.
Open vent pipes that extend through a roof shall be terminated at least 6 inches 152 mm above the roof or 6 inches 152 mm above the anticipated snow accumulation whichever is greater except that where a roof is to be used for any purpose other than weather protection the vent extension shall be run at least 7 feet 2134 mm above the roof.
The horizontal portion of a revent pipe must be at least 6 inches above the fixture s flood level the highest point to which water can rise.
This calculation from example 1 alone would give you a solid working height but if you are close to your peak then you might have more pipe height than you actually need.
The soil pipe also known as the vent stack or stack pipe provides air for the plumbing system.
This may seem suitable since the only purpose for the stack is to provide air and expel sewer gases.
On a sink the flood level is the sink rim or overflow hole.
Extension of vent pipes through a roof shall be terminated not less than 12 inches above it.
I didn t build this house and the plumber just has a 3 inch vent pipe extending through the roof.
At least one of the primary 3 or 4 inch drainage stacks should continue up and through the roof without changing the pipe size.
Yes full sized vent pipes are a good idea.
Other smaller vent pipes from other fixtures can connect to this full sized vent pipe.
Open vent pipes that extend through a roof shall be terminated at least 6 inches 152 mm above the roof or 6 inches 152 mm above the anticipated snow accumulation whichever is greater except that where a roof is to be used for any purpose other than weather protection the vent extension shall be run at least 7 feet 2134 mm above the roof.
Vent pipes should extend to outdoors above the building roof and should terminate vertically not less than 6 above the roof surface nor more than 24 and must be at least 12 from any vertical surface such as a nearby sidewall.
You can connect the kitchen vent to the main vent in the attic as long as the main vent is the proper size and extends through the roof.
It should have been 4 inches.
Above the roof plumbing vent height.
Depending on your region the vent stack may protrude only a few inches above the surface of the roof.
In other words the highest point within a 10 foot circle of the pipe.
Drainpipe serving a single family home needs a main vent that is at least 1 1 2 in.
Vents are required to be at least half the diameter of the drainpipe that they serve so a 3 in.