A vent terminal and depending if the roof is strictly for weather protection it terminates about 24 above the roof.
How fr above the roof does a vent.
Let s look at a couple of examples.
If the pipe is farther than 10 feet from the roof peak.
Where a roof is used for any purpose other than weather protection vents shall extend at least 7 feet above the roof and shall be properly supported.
According to the uniform plumbing code the soil pipe or stack pipe shall extend vertically not less than six 6 inches.
For those stinky vents consider installing odor hog vent caps see image on the roof vents.
We install our roof vents 6 to 8 inches above the roof line.
Distance matters the top of a chimney pipe must extend at least 2 feet above the peak of the roof if the pipe is within 10 feet of the peak.
12 4 1 extension above roofs vent pipes shall terminate not less than 6 inches above the roof measured from the highest point where the vent intersects the roof.
A drip edge vent is made of a corrosive resistant material that sticks out about three inches back from the roof edge and then bends downward over them.
Match the vent pipe to the furnace maker s recommendations either sheet metal or vinyl.
If the roof area is for people then it is 7 ft above the roofing surface.
For 18 feet of run you would have a rise of 72 inches.
Slits in the product allow for air to flow into the attic.
So only use.
Above the roof plumbing vent height.
Vent pipes should extend to outdoors above the building roof and should terminate vertically not less than 6 above the roof surface nor more than 24 and must be at least 12 from any vertical surface such as a nearby sidewall.
Upc i 906 1 and 906 2.
You are close to your eave and you find that your measurement is 18 feet from peak to penetration on a 4 12 pitch see figure 3.
Organizations such as the nrca recommend against this roof vent style in cold climates because it can promote ice dams.
Run the vent pipe up through the roof and install a metal or pvc flashing collar over it.