Simply making sure your plumbing vent clears the roof line will not necessarily meet regulations.
How few pluming vents trhough roof.
The vent stack is the pipe leading to the main roof vent.
When water drains air must replace the space that was taken up by the water.
It is a vertical pipe attached to a drain line and runs through the roof of your home.
This would include structures such as the side wall or chimney.
Running a vent pipe out of the roof takes some careful preparation.
The plumbing vent must also be at least 10 feet from the nearest opening.
The plumbing vent pipe is a vertical pipe that attaches to the drain line and runs through the roof of a home.
Vent terminations near any air intakes on a roof must be a minimum of 3 feet above the intake opening or at least 10 feet away.
Vents are also required to be at least 7 feet above a roof when it is also used as a walking surface.
It also allows fresh air into the plumbing system to help water flow smoothly through the drain pipes however no water runs through the plumbing vent pipe.
Any increase in the size of the vent shall be made inside the structure a minimum of 1 foot 305 mm below the roof or inside the wall.
The pipe leading to the main roof vent is called the vent stack.
Plumbing vent pipes are connected to your drain system and are needed for water to drain properly.
It helps maintain proper atmospheric pressure in a building s waste system and channels the exhaust gasses to the vent.
It must also be at least 12 inches from the nearest vertical surface.